Telemetry

Telemetry controls permit to configure data to be stored or transmitted on the system. There are 4 main items that can be configured within this panel:

Type

Description

Data Link

Configures the variables to send throughout the data link channel.

Onboard Log

Sets the variables to be stored on system Log. (on Veronte SD Card)

User Log

User Log for custom applications.

Fast Log

Saves data at the maximum frequency available on the system. Recording time depends on the selected variables.

Configuration display permits to enable the desired variables for each telemetry file and to set the maximum and minimum values together with precision for each one.

Onboard Log

The Onboard Log determines the variables that are being stored on the autopilot SD Card. In this case, there are not sending/receiving units so the only thing to configure here is the list of variables that will be saved on the autopilot internal memory for a further download and processing. The SD management task is Low, which is an execution level running at 30 Hz.

Veronte Configuration - Onboard Log

Onboard Log

User Log

The user log contains the variables that are stored according to an automation created by the user. Considering an example, in a photogrammetry mission it is important to record the aircraft location when the photo is taken, so a user log could be used to record a certain set of variables (position, speed, direction…) each time a photo is taken.

Veronte Configuration - User Log

User Log

In order to create a User Log action where an entry is added to the log when a certain set of events are accomplished check ref section 6.9 of the manual (Actions).

Fast Log

The fast log store the specified variables at the maximum rate available on the system. This tool could be used to save information in an operation that happens extremely fast such as missile launching. The time that this logging process lasts depends on the number of variables being saved.

When a variable is enabled in the Fast Log, a new button will appear in the Veronte Panel. The user must click on it when he wants to activate the fast log tool.

Veronte Configuration - Fast Log button

Fast Log button

The downloading of the information of an operation depends on how it has been stored, i.e depends on the type of log (data link, onboard, user or fast). Visit section 10 of the manual to see the information related to the postflight tools contained in Veronte Pipe.