Mounting

Cable Connection

Package content includes the following cable. One connector must be connected to Veronte Autopilot and the other one to the CS Cable or the Aircraft connector in case of HIL Simulation using the complete platform system.

Simulation - HIL Simulation - HIL Simulator Cable

HIL Simulator Cable

Veronte Pipe Configuration

There are 2 configuration items on Veronte Pipe, one relating communications between the application and the X-Plane simulator and another one refereeing the autopilot configuration.

Autopilot Configuration

HIL simulation tab is available within Veronte Autopilot setup toolbar. The user can link the variables on Veronte Autopilot with the corresponding ones in X-Plane simulator.

Simulation - HIL Simulation - HIL Setup

Veronte Pipe – HIL Setup

In this panel, X-Plane variables are available on the left side (Disables). In addition, it can be seen two section more To XPlane and To Veronte.

In order to configure the simulation variables, users have to:

  1. Enable the ones that have been configured in the aircraft model (Plane Marker). Just drag and drop them into To Xplane section.

    Warning

    Always make sure that surfaces are moving in the right direction and with the correct deflection angle.

    To avoid mistakes is possible to set a positive fixed deflection (Control Tab) in Standby phase for all surfaces and control surface deflections in the X-Plane model.

    Surface control variables are of two types:

    • Radians measure (variables with numbers)

    • Degrees measure (variables with no numbers)

  2. Once X-Plane variables have been enabled, select the actuator variable (Control Output) that matches with the ones in Veronte autopilot. A new window will be displayed for each variable.

    Simulation - HIL Simulation - Selection
  3. Set a Conversion Factor or Offset, if it is necessary. Conversion factor multiplies the Veronte output signal and can be used in case units on Veronte and the X-Plane simulator do not match (Surfaces in X-Plane move normally in a [0,1] range). The following operation allows to converting an angle [deg] measure to the X-Plane form:

    (Angle + Offset) Conv.Factor = …

    When Angle and Offset are measured in [rad] and the Conversion factor is a constant (normally it can be calculated as 1/(deflection angle in [rad]).

    In the case of [rad] measures, the Conversion factor must be set in 57,29578 ([deg]-[rad] conv. factor).

    Finally, it is necessary to configure the communication between Veronte Pipe and X-Plane, see section below.

Veronte Pipe Communications

In order to start the simulation, select the HIL option (1) on the Veronte Unit, this is available on the side menu . Popup screen will be displayed (2) for selecting the kind of simulation and configuring the parameters.

Simulation - HIL Simulation - HIL Communications

Veronte Pipe – HIL Communications

Changing the default values is only recommended for advanced users. Press start in order to start the data transfer between X-Plane and Veronte Autopilot.

Warning

The simulation must be started when the aircraft is in the Initial phase (the one that gets in once is powered). In this phase the X-Plane will simulate the GPS signal to locate the autopilot in the place indicated by the airport on X-Plane.