L200 Catapult

Examples - L200 Catapult

L200 Catapult

From the Embention website it is possible to download User Manual and the Datasheet of the L200 Catapult.

Configuration

In order to configure correctly the launch system, it is necessary to perform two different actions:

  • Trimming of the launch actuator.

  • Create the automation for the launch button.

To set them, it is necessary to connect the catapult to Veronte Ground using the catapult wire and completing the system with a PC connection with Veronte Pipe.

Actuator Trimming

To trim the actuator it is necessary to create the catapult actuator by following the path Devices>Control>Actuators.

  1. Click on Change size actuators and select the actuator number (1) from the window.

    Examples - Catapult actuator trimming

    Catapult actuator trimming

  2. Once created an actuator, it is possible to trim it. Default values are shown in the previous figure, but user must be sure the servo can move covering all useful range, from bottom to top (0-1).

Launch Automation

The automation must be created in the Ground autopilot. The typical Event of the automation is a Button which will appear in the Ground Veronte Panel.

Examples - Automation Event

Automation Event

The Action is the change from 0 to 1 of the actuator value. A second value of the actuator should be set in order to restore the initial null value (in this case, after 2 seconds).

Examples - Automation Action

Automation Action